Xi'an Kacise Optronics Co., Ltd.
Give me a chance, give you a miracle!
Sales & Support 86-029-62929722
Select Language
English
Contact Us:

Xi'an Kacise Optronics Co., Ltd.

Address: Tangyan South Road, Yanta District, Xi'an, Shaanxi province, China

Phone: 86-029-62929722

I am Online Chat Now
Mrs. Evelyn(sales manager) Mrs. Evelyn(sales manager)
Home Products electromagnetic flow meter

GXEFM2000 series low cost electromagnetic flowmeter, electromagnetic flow meter

GXEFM2000 series low cost electromagnetic flowmeter, electromagnetic flow meter

1
GXEFM2000 series low cost electromagnetic flowmeter, electromagnetic flow meter
Product Details:
Place of Origin: China mainland
Brand Name: GX
Certification: CE
Model Number: GXEFM2000
Payment & Shipping Terms:
Minimum Order Quantity: 1 pc
Price: 30~150USD
Packaging Details: 1 pc/box, many boxes per carton, or customised available.
Delivery Time: Asap. after payment
Payment Terms: L/C, D/A, D/P, T/T, Western Union, Money Gram
Supply Ability: 10000
Description

GXEFM2000 series low cost electromagnetic flowmeter, electromagnetic flow meter

 

 

Description

GXEFM2000 electromagnetic flow meters are intended for fluid measurement in most industries including water, wastewater, food and beverage, pharmaceutical and chemical.

There are two basic components of electromagnetic flow meter: 1) The Detector, which includes the flow tube, isolating liner and measuring electrodes, and 2) The Converter, which is the electronic device responsilbe for signal processing, flow calculation, display and output signals.

The materials of construction of the wetted parts( liner and electrodes) should be appropriate for the specification on the intended type of of service. Revies of the compatibilities consistent with the shipment of each meter.

Application field 

Petroleum, Chemical, Metallurgy, Textile, Papermaking, Environmental protection, Food industry and Municipal administration, Water conservancy construction, Heating heating engineering, River dredging and other fields.

 

Technical Data

 

Measuring system

 

Measuring principle

Faraday’s law

 

Application range

Electircally conductive fluids

Measured Value

Primary measured value

Flow velocity

Secondary measured value

Volume flow

 

 

 

Design

 

Features

Fully welded maintenance-free sensor

Flange version with full bore flow tube

Standard as well as higher pressure ratings

Large diameter range from DN15~3000 with

rugged liners approved for drinking water

Industry specific insertion lengths

Modular construction

The measurement system consists of a flow

Sensor and a signal converter. It is available as compact and as separate version

Compact version

With 511B converter: 110~240Vac Power

With 521B converter: 18~36V DC Power

With W800L/W800W: Battery Power

Remote version

In wall mount version with 211B converter

(110~240Vac or 221B converter 18~36V DC

With W800F converter: Battery Power

Measurement range

-12…+12m/s /-40...+40ft/s

 

 

 

Measuring accuracy

 

Reference conditions

Flow conditions similar to EN 29104

Medium: water

Electrical conductivity: 300μs/cm

Temperature: +10~+30/+50~+80

Inlet setion: 5DN

Operating pressure: 1Bar/14.5psig

Flow Meter Accuracy

Standard: 0.5% of rate

Optional: 0.2% of rate

 

 

 

Operating conditions

Temperature

Process temperature

Hard rubber liner: -5~+60

Polypropylene liner: -5~+90

PTEF liner: -5~+120

Ambient temperature

Standard (with aluminum converter housing)

-20~+60℃ (Protect electorics againgst self-heating with ambient temperature above 55

Stroage temperature

-20~70

Pressure

EN 1092-1

DN2200~3000: PN2.5

DN1200~2000: PN6

DN200~1000: PN10

DN65~150: PN16

DN10~50: PN40

Other pressure on request

ISO insertion length

Optional for DN15~600

ASME B16.5

1~24”: 150lb RF

Other pressure on request

JIS

DN10~1000/ 2~40”: 10K

Other pressure on request

Pressure drop

Negligible

 

Fluid

Physical condition

Conductive liquids

Electrical donductivity

5μs/cm

Permissible gas content (volume)

≤5%

Permissible solid content

70%

 

Installation conditions

Installation

Take care that flow sensor is always fully filled

For detailed information see chapter “Cautions

for installation”

Flow direction

Forward and reverse

Arrow on flow sensor indicates positive flow

direction

Inlet run

≥5 DN

Outlet run

≥2 DN

 

Process connection

Flange

EN1092-1

DN25~3000 in PN6~40

ASME

1~120” in 150 lb RF

JIS

25~1000 in 10~20k

Design of gasket surface

RF

 

Other sizes or pressure ratings on request

Product picture 

GXEFM2000 series low cost electromagnetic flowmeter, electromagnetic flow meter

GXEFM2000 series low cost electromagnetic flowmeter, electromagnetic flow meter

GXEFM2000 series low cost electromagnetic flowmeter, electromagnetic flow meter

 

Other about
Contact Us
Mrs. Evelyn
  • Tangyan South Road, Yanta District, Xi'an, Shaanxi province, China
  • p.86-029-62929722
  • f.86-029-88888109
From:
Enter your Email ID please.
Send your inquiry directly to us
(77/3000)